MicroplateReader

240x128 LCD, full keyoperating system

  • Brand:REAGEN
  • Model:RNE90002
  • Sensitivity:5948.00USD

RNE90002 Microplate Reader

image55.jpg

Introduction

1)RNE90002 is a microprocessor –controlled, general purpose photometer system designed to read and calculate the result of assays, including contagion, tumorous mark, hemopathy, dyshormonism, which are read in microtiter plate.

2)Touch panel let your operation easily.


3)Multiple calculations:


lAbsorbance mode (ABS)


lCut-Off mode


lSingle standard mode


lPoint to point mode


l% Absorbance Multi-Point Mode


lLinear regression mode


lExponent regression mode


lLogarithm regression mode


lPower regression mode


4) isualization mark plate,you can set blank, 


control, sample ,standard in any place,and


run mostly 12 different tests in one 96 micr


plate.


5) Test time <5s/plate,and mix plate before


test

6)Item parameter settings: parameters of 120 detection items can be set, saved and queried for future detection;

7)Detection calibration: detection calibration is enabled, calibration parameters of 120 last items can be saved, calibration parameters can be transferred while do the same item

detection;  

                                         

Parameters of instrument

Weight:

8.1kg

Overall dimensions:

430mm(L)×335mm(W)×175mm(H)

Power:

a.c.110V~220V50-60Hz

Fuses:

T2AL250V

Work Environment:

temperature 10-30Humidity ≤70%

Store Environment:

-20-55Humidity ≤93%

Standard Wavelength:

405450492630nmTen optical fibers can be configured within 400 to 800 at a

time;

Instrument sensitivity:

no less than 0.01L/mg.

Instrument channel difference:

less than 0.01A.

Range of operating wavelength:

400-800nm;

Detection range:

0.000-4.000A;

Resolution ratio:

0.001A;

Plate reading velocity:

5s of single waveform, 10s of dual wavelength;

Warm up time:

10 minute

Interface:

RS-232C serial interface, USB interface

Display:

5.7″LCD display(320×240 discernibility,256 gray scale)

Input:

Touch panel and pen,

Accuracy

±0.01(0.000-2.000nm)

Linear error

±1.0%(0.000-2.000nm)

Accurate wavelength

±3.0nm



About Us

REAGEN LLC,focusing on ELISA,PCR,Lateral Flow testing  kits including clinical disease detecting kits,food&feed safety test kits and animal epidemic virus detecting kits in US for 11 years

Read More

Graphic

contact

  • 7098 Miratech Dr Ste 110 San Diego CA 92121 USA
  • 856-600-2115
  • Max@reagen.us
  • www.reagen.us